Standard version specifications
1 to 2 vertical outlet exhaust air exhaust fans with adjustable air flow
1 top with level detection system with ladder and guardrail
1 drying column including: 4 to 14 duct drying bays (depending on model). 1 to 4 bays can be used for cooling (depending on model) with the dampers and doors
1 exhaust air plenum
1 hot air plenum with glass wool insulated panels, circulating hot air through the drying bays.
1 adjustable hot air generator
1 pre-drying grain pre-ventilation system
1 pneumatic discharge system
1 standard control unit including:
1 PLC controlling the fan, burner, pneumatic extractor with proportional grain flow control for even drying regardless of inlet moisture
Hot air safety, grain safety
Grain level
Handling control
1 dryer control and display touch panel with settings recall and alarm
Connected to the Internet and GSM networks
Reduced dust emissions with dampers (optional) and rotary vacuum cleaning filters
Built-in pre-cleaner (optional)