OverviewIAS-HerbPro adopts exclusive rapid mixing technology, allowing setting of mixing average times in the software based on sample form for more accurate results. Powerful functions and easy-to-operate features allow you to focus more on important work.
The instrument adopts advanced digital exposure spectroscopy technology, demonstrating excellent sensitivity and precision in a compact integrated design. Obtain non-destructive results within 1 minute, avoiding costly rework and errors from manual operations, saving valuable resources. IAS-HerbPro adapts to diverse usage scenarios such as offices, workshops, production sites, laboratories, fields, etc., allowing anyone to start multiple component detections of the test object with one click anytime, anywhere.
Key Features- Exclusive rapid mixing technology with configurable mixing average times per sample form
- Advanced digital exposure spectroscopy for high sensitivity and precision
- Non-destructive measurement delivering results within 1 minute
- Compact integrated design suitable for offices, workshops, production sites, laboratories and field use
- User-friendly operation enabling one-click multi-component detection
Applications (table)- Alfalfa Hay — Moisture (Dry Matter), Crude Protein, Crude Fat, Crude Ash, ADF, NDF, RFV, RFQ
- Oat Hay — Moisture (Dry Matter), Crude Protein, Crude Fat, Crude Ash, ADF, NDF, WSC (Water-Soluble Carbohydrates), RFV, RFQ
- Alfalfa Silage — Moisture (Dry Matter), Crude Protein, Crude Fat, Crude Ash, ADF, NDF, PH, Lactic Acid, Acetic Acid, Ammonia Nitrogen, RFV, RFQ
- Oat Silage — Moisture (Dry Matter), Crude Protein, Crude Fat, Crude Ash, ADF, NDF, WSC, PH, Lactic Acid, Acetic Acid, Ammonia Nitrogen, RFV, RFQ
- Whole Plant Corn — Moisture (Dry Matter), Crude Protein, Crude Fat, Crude Ash, ADF, NDF, Starch, RFV, RFQ
- Corn Silage — Moisture (Dry Matter), Crude Protein, Crude Fat, Crude Ash, ADF, NDF, Starch, PH, Lactic Acid, Acetic Acid, Ammonia Nitrogen, RFV, RFQ
Sampling Accessory (table)- Sampling Accessory 1 — suitable for fluffy, segmented, granular samples, suitable for rapid mixing detection in the field
- Sampling Accessory 2 — suitable for fluffy, segmented, granular samples, suitable for laboratory detection
Technical Specifications (table)- Wavelength Range (NIR) — 950-1650 nm
- Detector — InGaAs Detector (256 pixels)
- Spectroscopic Principle — Grating + Array Detector
- Baseline Noise — ≤0.0001 AU
- Wavelength Repeatability — ≤0.005 nm
- Wavelength Accuracy — ≤2 nm
- Absorbance Repeatability — ≤0.0001 AU
- Measurement Time — ≤1 min
- Light Source — Tungsten Halogen Lamp
- Dimensions — L:265mm / W:340.5mm / H:262.3mm
- Weight — 9 Kg
- Data Interval — 1 nm
- Power Supply — 24V/3A
- Power Consumption — 25W (average)
- Display Screen — 7-inch Touch Screen
- Built-in Operating System — Linux
- Operating/Storage Temperature — 5-45 °C / -20-60 °C
- Operating Humidity — <75% RH
Technical specifications summary- Wavelength Range (NIR): 950-1650 nm
- Detector: Indium Gallium Arsenide (InGaAs), 256 pixels
- Spectroscopic Principle: Grating + Array Detector
- Baseline Noise: ≤0.0001 AU
- Wavelength Repeatability: ≤0.005 nm
- Wavelength Accuracy: ≤2 nm
- Absorbance Repeatability: ≤0.0001 AU
- Measurement Time: ≤1 minute (non-destructive)
- Light Source: Tungsten Halogen Lamp
- Dimensions: 265 × 340.5 × 262.3 mm
- Weight: 9 Kg
- Data Interval: 1 nm
- Power Supply: 24V / 3A
- Power Consumption: 25 W (average)
- Display: 7-inch touch screen
- OS: Linux (built-in)
- Operating Temperature: 5–45 °C; Storage Temperature: -20–60 °C
- Operating Humidity: <75% RH