1. Farm Infrastructure
  2. Waste management
  3. Sheep waste incinerator
  4. Agri Incineration Systems (AIS Incinerators)

Sheep waste incinerator 026 Cyclone
cattlefor pigspoultry

Sheep waste incinerator - 026 Cyclone - Agri Incineration Systems (AIS Incinerators) - cattle / for pigs / poultry
Sheep waste incinerator - 026 Cyclone - Agri Incineration Systems (AIS Incinerators) - cattle / for pigs / poultry
Sheep waste incinerator - 026 Cyclone - Agri Incineration Systems (AIS Incinerators) - cattle / for pigs / poultry - image - 2
Sheep waste incinerator - 026 Cyclone - Agri Incineration Systems (AIS Incinerators) - cattle / for pigs / poultry - image - 3
Sheep waste incinerator - 026 Cyclone - Agri Incineration Systems (AIS Incinerators) - cattle / for pigs / poultry - image - 4
Sheep waste incinerator - 026 Cyclone - Agri Incineration Systems (AIS Incinerators) - cattle / for pigs / poultry - image - 5
Add to favorites
Compare this product

Characteristics

Application
poultry, for pigs, sheep, cattle

Description

Overview
Reliable mid-class incinerator for on‑site biosecure disposal of animal carcasses and mixed agricultural by-products. Hand-built with a monolithic concrete refractory lining, PLC controls and temperature-controlled burners. 190 kg chamber load capacity; up to 50 kg/hr burn rate. Fuel: Diesel, LPG or Natural Gas. Supplied with a 3-year standard warranty.

Suitable for
  • Poultry and broilers
  • Pigs and piglets
  • Cattle and calves
  • Sheep and lambs
  • Game farms, estates, small abattoirs and farm shops

Main features
  • Front-loading main chamber for ground-level loading and safe on-site handling
  • Monolithic cast concrete refractory lining for thermal retention and efficient combustion
  • Temperature-controlled burners with fast ignition
  • PLC timer controls with automatic burner shut-off and simple operator interface
  • One temperature-controlled burner in the main chamber and one in the secondary chamber
  • Designed to allow loading while in operation to maximise thermal efficiency and reduce running costs
  • Optional ash door and grate bars available

Optional extras
  • Animal loading trolley / winch assembly
  • USB data logger
  • Ash door
  • Stack extensions
  • Ash rake
  • Simple heat exchange system
  • Control panel screen size increase
  • Service kits

Full specification (Metric — Imperial)
Burn Rate — Up to 50 kg/hr — Up to 110 lbs/hr
Front / Top Load — Front — Front
Operational Dimensions Static (L x W x H) — 1.9 x 1.7 x 5.1 m — 6'3" x 5'5" x 16'9"
External Height Static (inc. stack) — 5100 mm inc. Stack — 16'9" inc. Stack
External Height Static (ex. stack) — 2412 mm ex. Stack — 7'11" ex. Stack
Weight Static — 2.4 Tonne estimated — 5292 lbs estimated
Load Height from Ground (floor to bottom edge) — 325 mm — 1'1"
Fuel Consumption Diesel — 6.9 – 10.5 LPH est during main burn — 1.8 – 2.8 GPH est during main burn
Fuel Consumption LPG — 9 – 16 LPH est during main burn — 1.7 – 4.1 GPH est during main burn
Fuel Consumption Natural Gas — 7 – 10 m³/h est during main burn — 243 – 370 ft³/h est during main burn
Grate Bars — No — No
Load Door Opening (Width x Height/Depth) — 900 x 710 mm area — 2'11" x 2'4" area
Chamber Size (L x W x H) — 1.2 x 0.9 x 0.7 m — 3'10" x 2'11" x 2'4"
Chamber Actual Volume — 0.74 m³ — 26 ft³
Chamber Load Volume — 0.34 m³ — 12 ft³
Chamber Load Capacity — 190 kg — 419 lbs
Std Stack Diameter — 10" — 10"
No. Main Burners — 1 — 1
No. Secondary Burners — 1 — 1
Burner Output — 159 kW heat — 542,531 Btu heat
Electric Consumption — 0.25 kW electricity — 0.25 kW electricity

Technical specifications
  • Model: AIS 026 Cyclone
  • Capacity per cycle: 190 kg (419 lbs)
  • Typical burn rate: up to 50 kg/hr (up to 110 lbs/hr)
  • Fuel options: Diesel / LPG / Natural Gas
  • Burner output: 159 kW (approx.)
  • Main burners: 1; Secondary burners: 1
  • Refractory: Monolithic concrete lining
  • Controls: PLC with automatic burner shut-off and timer controls
  • Loading: Front-loading door; load height from ground 325 mm
  • Chamber size: 1.2 x 0.9 x 0.7 m (chamber volume 0.74 m³)
  • Chamber load volume: 0.34 m³ (12 ft³)
  • Operational dimensions (LxWxH): 1.9 x 1.7 x 5.1 m
  • Weight (static): approx. 2.4 tonne
  • Fuel consumption (estimated during main burn): Diesel 6.9–10.5 LPH; LPG 9–16 LPH; Natural Gas 7–10 m³/h
  • Electric consumption: 0.25 kW
  • Standard stack diameter: 10"
  • Load door opening area: 900 x 710 mm
  • Warranty: 3 years standard
  • Build: Hand-built in UK & US