OverviewReliable mid-class incinerator for on‑site biosecure disposal of animal carcasses and mixed agricultural by-products. Hand-built with a monolithic concrete refractory lining, PLC controls and temperature-controlled burners. 190 kg chamber load capacity; up to 50 kg/hr burn rate. Fuel: Diesel, LPG or Natural Gas. Supplied with a 3-year standard warranty.
Suitable for- Poultry and broilers
- Pigs and piglets
- Cattle and calves
- Sheep and lambs
- Game farms, estates, small abattoirs and farm shops
Main features- Front-loading main chamber for ground-level loading and safe on-site handling
- Monolithic cast concrete refractory lining for thermal retention and efficient combustion
- Temperature-controlled burners with fast ignition
- PLC timer controls with automatic burner shut-off and simple operator interface
- One temperature-controlled burner in the main chamber and one in the secondary chamber
- Designed to allow loading while in operation to maximise thermal efficiency and reduce running costs
- Optional ash door and grate bars available
Optional extras- Animal loading trolley / winch assembly
- USB data logger
- Ash door
- Stack extensions
- Ash rake
- Simple heat exchange system
- Control panel screen size increase
- Service kits
Full specification (Metric — Imperial)Burn Rate — Up to 50 kg/hr — Up to 110 lbs/hr
Front / Top Load — Front — Front
Operational Dimensions Static (L x W x H) — 1.9 x 1.7 x 5.1 m — 6'3" x 5'5" x 16'9"
External Height Static (inc. stack) — 5100 mm inc. Stack — 16'9" inc. Stack
External Height Static (ex. stack) — 2412 mm ex. Stack — 7'11" ex. Stack
Weight Static — 2.4 Tonne estimated — 5292 lbs estimated
Load Height from Ground (floor to bottom edge) — 325 mm — 1'1"
Fuel Consumption Diesel — 6.9 – 10.5 LPH est during main burn — 1.8 – 2.8 GPH est during main burn
Fuel Consumption LPG — 9 – 16 LPH est during main burn — 1.7 – 4.1 GPH est during main burn
Fuel Consumption Natural Gas — 7 – 10 m³/h est during main burn — 243 – 370 ft³/h est during main burn
Grate Bars — No — No
Load Door Opening (Width x Height/Depth) — 900 x 710 mm area — 2'11" x 2'4" area
Chamber Size (L x W x H) — 1.2 x 0.9 x 0.7 m — 3'10" x 2'11" x 2'4"
Chamber Actual Volume — 0.74 m³ — 26 ft³
Chamber Load Volume — 0.34 m³ — 12 ft³
Chamber Load Capacity — 190 kg — 419 lbs
Std Stack Diameter — 10" — 10"
No. Main Burners — 1 — 1
No. Secondary Burners — 1 — 1
Burner Output — 159 kW heat — 542,531 Btu heat
Electric Consumption — 0.25 kW electricity — 0.25 kW electricity
Technical specifications- Model: AIS 026 Cyclone
- Capacity per cycle: 190 kg (419 lbs)
- Typical burn rate: up to 50 kg/hr (up to 110 lbs/hr)
- Fuel options: Diesel / LPG / Natural Gas
- Burner output: 159 kW (approx.)
- Main burners: 1; Secondary burners: 1
- Refractory: Monolithic concrete lining
- Controls: PLC with automatic burner shut-off and timer controls
- Loading: Front-loading door; load height from ground 325 mm
- Chamber size: 1.2 x 0.9 x 0.7 m (chamber volume 0.74 m³)
- Chamber load volume: 0.34 m³ (12 ft³)
- Operational dimensions (LxWxH): 1.9 x 1.7 x 5.1 m
- Weight (static): approx. 2.4 tonne
- Fuel consumption (estimated during main burn): Diesel 6.9–10.5 LPH; LPG 9–16 LPH; Natural Gas 7–10 m³/h
- Electric consumption: 0.25 kW
- Standard stack diameter: 10"
- Load door opening area: 900 x 710 mm
- Warranty: 3 years standard
- Build: Hand-built in UK & US