1. Farm Infrastructure
  2. Waste management
  3. Sheep waste incinerator
  4. Agri Incineration Systems (AIS Incinerators)

Sheep waste incinerator 3860 Cyclone
cattlefor pigspoultry

Sheep waste incinerator - 3860 Cyclone - Agri Incineration Systems (AIS Incinerators) - cattle / for pigs / poultry
Sheep waste incinerator - 3860 Cyclone - Agri Incineration Systems (AIS Incinerators) - cattle / for pigs / poultry
Sheep waste incinerator - 3860 Cyclone - Agri Incineration Systems (AIS Incinerators) - cattle / for pigs / poultry - image - 2
Sheep waste incinerator - 3860 Cyclone - Agri Incineration Systems (AIS Incinerators) - cattle / for pigs / poultry - image - 3
Sheep waste incinerator - 3860 Cyclone - Agri Incineration Systems (AIS Incinerators) - cattle / for pigs / poultry - image - 4
Sheep waste incinerator - 3860 Cyclone - Agri Incineration Systems (AIS Incinerators) - cattle / for pigs / poultry - image - 5
Sheep waste incinerator - 3860 Cyclone - Agri Incineration Systems (AIS Incinerators) - cattle / for pigs / poultry - image - 6
Add to favorites
Compare this product

Characteristics

Application
poultry, for pigs, sheep, cattle
Other characteristics
high-capacity, mobile

Description

Overview
The flagship and largest Cyclone model, hand-built by Agri Incineration Systems (AIS). Supplied with a 3-year warranty as standard. Designed for on-site, biosecure disposal of large volumes of animal waste with a capacity of 3,750 kg per cycle and a burn rate up to 1,000 kg/hr.

Suitable for
  • Poultry
  • Pigs & sows
  • Dairy and beef cattle
  • Sheep
  • Equine / horses
  • Abattoirs and slaughterhouses
  • Rendering operations and meat processors
  • Large carcasses and mixed agricultural waste


Key features
  • Loading capacity up to 3,750 kg (8,269 lbs) per cycle
  • Burn rate up to 1,000 kg/hr (approx. 2,205 lbs/hr)
  • Fuel options: Diesel, LPG, Natural Gas
  • Top-loading with fully automated lid for easy, safe access
  • Five main burners (two above grate bars, three below) plus two secondary burners
  • Fully programmable touch-screen HMI and PLC control with automatic burner shut-off and fast ignition
  • Monolithic concrete refractory lining for thermal efficiency
  • Unique grate-bar configuration for rapid, complete incineration
  • Ash doors fitted as standard to remove ash while in operation
  • Built-in multi-channel thermocouple data logger and USB data logging option
  • Available as Static, Mobile, or Transportable configuration
  • Optional extras: Stack extension, ash rake, heat exchanger, larger control panel, service kits, remote monitoring


At a glance
  • Capacity: 3,750 kg / 8,269 lbs
  • Burn rate: up to 1,000 kg/hr
  • Fuel: Diesel / LPG / Natural Gas
  • Burner output: 1,197 kW (4,084,334 Btu)
  • Warranty: 3 years standard
  • Build: Hand-built (UK & US)


Full specification (selected rows)
Burn Rate: Up to 1000 kg/hr — Up to 2205 lbs/hr
Front / Top Load: Top
Static Operational Dimensions (L x W x H): 10.4 x 2.8 x 4.9 m
External Height - Static (inc. Stack): 4857 mm inc. Stack
External Height - Static (ex. Stack): 2754 mm ex. Stack
Weight: 21.4 Tonne estimated (≈ 47,179 lbs estimated)
Load Height from Ground (floor to bottom edge): 1750 mm (5'9")
Fuel Consumption Diesel: 51 - 77 LPH est during main burn
Fuel Consumption LPG: 75 - 116 LPH est during main burn
Fuel Consumption Natural Gas: 51 - 77 m³/h est during main burn
Grate Bars: 60
Load Door Opening (W x H/Depth): 3955 x 1900 mm area (≈ 13' x 6'3")
Chamber Size (L x W x H): 4.0 x 1.9 x (1.5 - 2.1) m
Chamber Actual Volume: 11.00 m³ (388 ft³)
Chamber Load Volume: 6.81 m³ (241 ft³)
Chamber Load Capacity: 3750 kg (8269 lbs)
Std Stack Diameter: 625 mm
No. Main Burners: 5
No. Secondary Burners: 2
Burner Output: 1197 kW heat (4,084,334 Btu heat)
Electric Consumption: 3.25 kW electricity

What it does / Who it’s for
  • Designed for on-site disposal of fallen stock and animal by-products across farms, processors and emergency response operations
  • Secondary chamber maintains at least 850 °C for a minimum two-second residence time to meet combustion standards
  • Engineered for disease-control and emergency response capable operation


Loading & Controls
  • Top-loading with a fully automated lid providing complete access to the main burning chamber; can be loaded while in operation
  • PLC control with auto burner shut-off; programmable touch-screen HMI for cycle control and diagnostics
  • Built-in thermocouple data logger and USB logging for run time and temperature records; remote monitoring available as an option


Technical specifications
  • Model: AIS 3860 Cyclone
  • Capacity per cycle: 3,750 kg
  • Burn rate (approx.): 1,000 kg/hr
  • Fuel types: Diesel / LPG / Natural Gas
  • Refractory: Monolithic concrete lining
  • Loading type: Top-loading
  • Controls: PLC with automatic burner shut-off; touch-screen HMI
  • Warranty: 3 years standard
  • Build origin: Hand-built in UK & US
  • Burner output: 1,197 kW
  • Electric consumption: 3.25 kW
  • Chamber actual volume: 11.00 m³
  • Chamber load volume: 6.81 m³
  • Estimated weight: 21.4 Tonne
  • Standard stack diameter: 625 mm
  • Main burners: 5; Secondary burners: 2