1. Farm Infrastructure
  2. Waste management
  3. Sheep waste incinerator
  4. Agri Incineration Systems (AIS Incinerators)

Sheep waste incinerator 040 Cyclone
cattlefor pigspoultry

Sheep waste incinerator - 040 Cyclone - Agri Incineration Systems (AIS Incinerators) - cattle / for pigs / poultry
Sheep waste incinerator - 040 Cyclone - Agri Incineration Systems (AIS Incinerators) - cattle / for pigs / poultry
Sheep waste incinerator - 040 Cyclone - Agri Incineration Systems (AIS Incinerators) - cattle / for pigs / poultry - image - 2
Sheep waste incinerator - 040 Cyclone - Agri Incineration Systems (AIS Incinerators) - cattle / for pigs / poultry - image - 3
Sheep waste incinerator - 040 Cyclone - Agri Incineration Systems (AIS Incinerators) - cattle / for pigs / poultry - image - 4
Sheep waste incinerator - 040 Cyclone - Agri Incineration Systems (AIS Incinerators) - cattle / for pigs / poultry - image - 5
Add to favorites
Compare this product

Characteristics

Application
poultry, for pigs, sheep, cattle
Other characteristics
high-capacity

Description

Overview
Designed for daily mortality and high-volume on-farm disposal. The AIS 040 Cyclone is a hand-built animal waste incinerator with a 540 kg (1,191 lb) load capacity, multi-fuel capability (Diesel, LPG, Natural Gas) and an integral monolithic refractory lining. Standard warranty: 3 years.

Suitable for
  • Poultry (broiler sites)
  • Pig and swine (including piglet mortality)
  • Cattle (calves)
  • Sheep and lamb
  • Mixed livestock and agricultural waste

Key specifications at a glance
  • Capacity: 540 kg / 1,191 lbs
  • Burn rate (approx.): up to 116 kg/hr (ROW); up to 50 kg/hr (UK, regulation dependent)
  • Fuel: Diesel / LPG / Natural Gas
  • Burner output: 226 kW (771,144 Btu)
  • Refractory: Monolithic concrete lining
  • Loading: Top-loading with counterbalance lid (compatible with skid loaders and tractor buckets)
  • Controls: PLC with automatic burner shut-off and timer
  • Warranty: 3 years standard
  • Build: Hand-built (UK & US)

Features
  • Top-loading design enables mechanical loading while maintaining thermal efficiency.
  • Two temperature-controlled main burners (above and below grate) plus a secondary chamber burner to meet combustion residence-time requirements.
  • Adjustable grate bars supplied as standard; ash falls to main chamber floor with ash doors for safe removal during operation.
  • Multi-zoned temperature monitoring and air control for fuel efficiency.
  • Regulation-dependent burn-rate options to align with local approval requirements.
  • Full access to main chamber for ease of loading and maintenance.

Optional extras
  • Grate Bars
  • USB Data Logger
  • Ash Door
  • Stack Extensions
  • Ash Rake
  • Heat Exchange
  • Larger Control Panel
  • Service Kits

Full specification
Burn Rate: Up to 50 (UK) / 116 (ROW) kg/hr — Up to 110 (UK) / 256 (ROW) lbs/hr
Front / Top Load: Top
Operational Dimensions (L x W x H): 3.4 x 3.0 x 3.2 m — 11'2" x 9'10" x 10'6"
External Height (inc. Stack): 3200 mm inc. Stack — 10'6" inc. Stack
External Height (ex. Stack): 2100 mm ex. Stack — 6'11" ex. Stack
Weight: 3.3 Tonne estimated — 7,276 lbs estimated
Load Height from Ground (floor to bottom edge): 1,256 mm — 4'1"
Fuel Consumption Diesel: 8.8–13.5 LPH (est during main burn) — 2.3–3.6 GPH (est)
Fuel Consumption LPG: 12–20 LPH (est) — 2.5–5.3 GPH (est)
Fuel Consumption Natural Gas: 9–13 m³/h (est) — 312–475 ft³/h (est)
Grate Bars: Yes
Load Door Opening (W x H/Depth): 2,148 x 1,060 mm area — 7'1" x 3'6"
Chamber Size (L x W x H): 2.2 x 1.1 x 0.6 m — 7'3" x 3'7" x 1'10"
Chamber Actual Volume: 1.33 m³ — 47 ft³
Chamber Load Volume: 0.98 m³ — 34 ft³
Chamber Load Capacity: 540 kg — 1,191 lbs
Std Stack Diameter: 16"
No. Main Burners: 2
No. Secondary Burners: 1
Burner Output: 226 kW heat — 771,144 Btu heat
Electric Consumption: 0.35 kW

FAQ (selection)
  • What can the AIS 040 Cyclone incinerate? Fallen stock and animal by-products including poultry, swine, lambs, calves and mixed agricultural waste, subject to local regulations.
  • What is the capacity and fuel type? Approx. 540 kg per cycle. Fuels: Diesel, LPG or Natural Gas; burn rate varies with load and moisture.
  • What combustion standard does it meet? Integral secondary chamber is designed to maintain ≥850 °C for a minimum two-second residence time; documentation provided to support local approvals.
  • What warranty is included? 3-year warranty covering chamber, refractory and burner assembly under normal use.
  • Are servicing and spares available? Servicing, thermocouples, refractory repairs and spare parts catalog are available.

Technical specifications
  • Model: AIS 040 Cyclone
  • Capacity per cycle: 540 kg / 1,191 lbs
  • Chamber size: 2.2 x 1.1 x 0.6 m (1.33 m³ actual; 0.98 m³ load)
  • Operational dimensions: 3.4 x 3.0 x 3.2 m
  • Burn rate: up to 50 kg/hr (UK) / up to 116 kg/hr (ROW)
  • Burner output: 226 kW
  • Fuel options: Diesel, LPG, Natural Gas
  • Refractory: Monolithic concrete lining
  • Loading: Top-loading with counterbalance lid
  • Controls: PLC with automatic burner shut-off and timer
  • Warranty: 3 years standard
  • Build: Hand-built (UK & US)

Catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About AgriExpo
AgriExpo is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. AgriExpo is an entity of VirtualExpo Group.