OverviewMid-class incinerator engineered for continuous-duty on agricultural sites. Hand-built in the UK and US with a monolithic concrete refractory lining, temperature-controlled burners and PLC controls. Supplied with a standard 3-year warranty.
What it does & who it's for- Designed for on-site bio-secure disposal of fallen stock and animal by-products.
- Targeted at small to medium farming operations: poultry, piglets to sows, sheep, game farms, estates, butchers and farm shops.
- Allows controlled disposal to support farm biosecurity and regulatory compliance.
Key performance figures- Load capacity: up to 290 kg (639 lbs).
- Burn rate: up to 50 kg/hour (up to 110 lbs/hour).
- Burner output: 150 kW (≈ 511,821 Btu).
- Fuel options: Diesel, LPG or Natural Gas.
- Continuous-duty design with monolithic concrete refractory lining for thermal efficiency.
Main features- Front-loading door for ground-level access to load larger carcasses safely.
- PLC timer controls with automatic burner shut-off and fast-ignition burners.
- One temperature-controlled burner in the main chamber and one in the secondary chamber.
- Can be loaded while in operation to maximise thermal efficiency and reduce operating time.
- Integral secondary chamber maintaining at least 850 °C for a minimum two-second residence time (combustion/approval support documentation available from AIS).
Optional extras- Animal loading trolley / winch assembly
- USB data logger
- Stack extensions
- Ash rake / ash door
- Simple heat exchange system
- Control panel screen size increase
- Service kits
GalleryOne installation image available showing AIS 041 Cyclone on site.
Full specification (metric / imperial)Load capacity — 290 kg / 639 lbs
Burn rate — Up to 50 kg/hr / Up to 110 lbs/hr
Load type — Front-loading (ground-level access)
Operational dimensions (L x W x H) — 2.4 x 1.6 x 3.1 m / 7'10" x 5'3" x 10'4"
External height (inc. stack) — 3140 mm / 10'4"
External height (ex. stack) — 1900 mm / 6'3"
Weight (static, est.) — 2.6 Tonne / 5,733 lbs (est.)
Load height from ground — 300 mm / ~1' (approx.)
Fuel consumption (Diesel, est. during main burn) — 6.8–10.4 LPH / 1.8–2.7 GPH
Fuel consumption (LPG, est. during main burn) — 9–15 LPH / 1.7–4.1 GPH
Fuel consumption (Natural Gas, est. during main burn) — 7–10 m³/h / 240–366 ft³/h
Grate bars — No
Load door opening (W x H area) — 900 x 700 mm / 2'11" x 2'4" area
Chamber size (L x W x H) — 1.9 x 0.9 x 0.7 m / 6'1" x 2'11" x 2'4"
Chamber actual volume — 1.20 m³ / 42 ft³
Chamber load volume — 0.52 m³ / 18 ft³
No. main burners — 1
No. secondary burners — 1
Burner output — 150 kW / 511,821 Btu
Electric consumption — 0.25 kW
NotesBurn rates, fuel consumption, weights and chamber capacities are estimates and depend on load type, moisture content and operating conditions.