Bio-secure on-site disposal for agricultural carcasses and animal by-products. Load capacity approx. 1,290 kg; burn rate up to 300 kg/hr. Fuel options: Diesel, LPG or Natural Gas. Hand-built in the UK & US. 3-year standard warranty.

Suitable for
  • Poultry, pigs & swine, cattle (dairy/beef), sheep & lamb, abattoirs, slaughterhouses, rendering plants and mixed agricultural waste


Key features
  • Available as Static, Mobile or Transportable incinerator
  • Top-loading design with manually operated slide open/close lid for full access to a large main burning chamber
  • PLC timer controls with automatic burner shut-off and fast ignition burners
  • Three main burners in the main chamber (one above the grate bars, two below) plus one secondary chamber burner
  • Market-leading grate bar technology (20 grate bars) for fast and complete incineration
  • Monolithic concrete refractory lining enabling loading during operation to maximise thermal efficiency
  • Ash doors as standard for safe ash removal while operating
  • Optional extras: automated lid, stack extension, ash rake, USB data logger, heat exchanger, larger control panel screen, service kits


At a glance
  • Capacity: 1,290 kg / 2,844 lbs
  • Burn rate (approx.): up to 300 kg/hr
  • Fuel: Diesel / LPG / Natural Gas
  • Burner output: 486 kW (1,658,301 Btu)
  • Refractory: Monolithic concrete lining
  • Loading: Top-loading (manual slide lid)
  • Controls: PLC with auto burner shut-off
  • Warranty: 3 years standard
  • Build: Hand-built in the UK & US


Full specification
Specification | Metric | Imperial
Burn Rate | Up to 300 kg/hr | Up to 661 lbs/hr
Capacity | 1,290 kg | 2,844 lbs
Fuel | Diesel / LPG / Natural Gas | Diesel / LPG / Natural Gas
Burner output | 486 kW heat | 1,658,301 Btu heat
No. Main Burners | 3 | 3
No. Secondary Burners | 1 | 1
Electric Consumption | 1.2 kW | 1.2 kW
Refractory | Monolithic concrete lining | Monolithic concrete lining
Loading | Top-loading | Top-loading
Controls | PLC with auto burner shut-off | PLC with auto burner shut-off
Warranty | 3 years standard | 3 years standard
Build | Hand-built UK & US | Hand-built UK & US

Dimensions & performance (selected values)
Static operational dimensions (L x W x H) | 4.6 x 2.8 x 4.9 m | 15' x 9'4" x 15'11"
External height (inc. stack) | 4,857 mm inc. stack | 15'11" inc. stack
External height (ex. stack) | 2,754 mm ex. stack | 9' ex. stack
Weight | 9.5 Tonne estimated | 20,944 lbs estimated
Load height from ground | 1,750 mm | 5'9"
Load door opening (area) | 1,335 x 1,900 mm | 4'5" x 6'3" area
Chamber size (L x W x H) | 1.3 x 1.9 x (1.5 - 2.1) m | 4'5" x 6'3" (4'11" - 7'3")
Chamber actual volume | 3.80 m³ | 134 ft³
Chamber load volume | 2.33 m³ | 82 ft³
Chamber load capacity | 1,290 kg | 2,844 lbs
Std stack diameter | 540 mm | 540 mm

Fuel consumption (estimates during main burn)
Diesel | 19 - 28 LPH est. | 4.9 - 7.5 GPH est.
LPG | 27 - 42 LPH est. | 6.3 - 11.2 GPH est.
Natural Gas | 19 - 28 m³/h est. | 656 - 999 ft³/h est.

Compliance & combustion
Integral secondary chamber designed to maintain at least 850 °C for a minimum two-second residence time to support approval against applicable local regulations.

Optional extras
  • Grate bars
  • USB data logger
  • Ash door or alternate ash handling
  • Stack extensions
  • Ash rake
  • Heat exchanger
  • Larger control panel / screen
  • Service kits


Technical specifications
  • Model: AIS 1250 Cyclone
  • Brand: Agri Incineration Systems (AIS)
  • Capacity per cycle: approx. 1,290 kg (2,844 lbs)
  • Burn rate: up to 300 kg/hr (approx.)
  • Fuel types: Diesel, LPG, Natural Gas
  • Burner output: 486 kW (1,658,301 Btu)
  • Number of main burners: 3; secondary burners: 1
  • Refractory: Monolithic concrete lining
  • Loading method: Top-loading (manual slide lid)
  • Controls: PLC with automatic burner shut-off and timer controls
  • Standard features: Ash doors, loadable during operation, market-leading grate bar technology (20 bars)
  • Chamber size (L x W x H): 1.3 x 1.9 x (1.5 - 2.1) m; chamber volume: 3.80 m³; load volume: 2.33 m³
  • Static operational footprint: 4.6 x 2.8 x 4.9 m (L x W x H)
  • Estimated weight: 9.5 Tonne
  • Electric consumption: 1.2 kW
  • Warranty: 3 years standard
  • Build: Hand-built in the UK & US

Catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About AgriExpo
AgriExpo is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. AgriExpo is an entity of VirtualExpo Group.