OverviewHand-built animal waste incinerator designed for on‑site disposal of fallen stock and animal by-products. Capacity 490 kg (1,080 lbs); loadable while operating to maximise throughput and thermal efficiency. Fuel options: Diesel, LPG, Natural Gas. Ships with a 3-year warranty as standard.
Suitable for- Poultry
- Pig and swine (growers, finishers, sows)
- Cattle, calves
- Sheep and lamb
- Game farms, estates, butchers and farm shops
Key performance- Capacity: 490 kg (1,080 lbs)
- Burn rate: Up to 50 kg/hr (approx.)
- Burner output: 193 kW (658,543 Btu)
- Fuel: Diesel, LPG, Natural Gas
- Electric consumption: 0.3 kW
Design & operation- Top-loading main chamber with counterbalance lid for loading via skid loaders or tractor buckets.
- Two temperature‑controlled main burners and one secondary burner with fast ignition.
- PLC timer controls with automatic burner shut‑off and monitoring.
- Integral secondary chamber maintains ≥850 °C for a minimum two‑second residence time to meet combustion performance requirements.
- Monolithic concrete refractory lining to maximise thermal efficiency and reduce running costs.
- Can be loaded during operation to maintain throughput and operational continuity.
- Optional extras: Grate Bars, USB Data Logger, Ash Door, Stack Extensions, Ash Rake, Simple Heat Exchange system, Larger Control Panel, Service Kits.
At a glance / HighlightsHand-built in the UK & U.S., the AIS 055 Cyclone offers top-loading operation, robust refractory lining, PLC controls and temperature‑controlled burners. Suited to commercial pig units and mixed agricultural operations requiring on-site biosecure disposal.
Full specification (selected)Capacity: 490 kg / 1,080 lbs
Burn rate: Up to 50 kg/hr (approx.)
Front / Top Load: Top
Operational Dimensions (L x W x H): 3.3 x 2.2 x 3.3 m (10'10" x 7'3" x 10'10")
External Height (inc. Stack): 3,300 mm (inc. stack)
External Height (ex. Stack): 2,198 mm (ex. stack)
Weight (est.): 2.9 Tonne (≈ 6,394 lbs)
Load Height from Ground: 1,000 mm (3'3")
Fuel consumption (Diesel, est.): 7.5–11.4 LPH (main burn)
Fuel consumption (LPG, est.): 10–17 LPH (main burn)
Fuel consumption (Natural Gas, est.): 7–11 m³/h (main burn)
Chamber size (L x W x H): 2.2 x 0.9 x 0.9 m
Chamber actual volume: 1.68 m³; Chamber load volume: 0.88 m³
Load door opening (W x H/Depth): 2,200 x 900 mm
Std stack diameter: 16"
No. main burners: 2; No. secondary burners: 1
FAQ highlights- Designed for on‑site disposal of fallen stock and animal by‑products; suitability should be confirmed against local regulations for each installation.
- Load capacity approximately 490 kg per cycle; burn rate and consumption vary with load type and operating conditions.
- Secondary chamber maintains required temperature and residence time; AIS provides documentation to support local approvals.
- 3‑year warranty standard covering chamber, refractory and burner assembly under normal use.
- Servicing and spare parts available, including thermocouples and refractory repair kits.
Technical specifications- Model: AIS 055 Cyclone
- Capacity (chamber load): 490 kg / 1,080 lbs
- Burn rate (approx.): Up to 50 kg/hr
- Fuel options: Diesel / LPG / Natural Gas
- Burner output: 193 kW (658,543 Btu)
- Refractory: Monolithic concrete lining
- Loading: Top-loading (counterbalance lid)
- Controls: PLC with timer and automatic burner shut‑off
- Operational dimensions (L x W x H): 3.3 x 2.2 x 3.3 m
- Chamber (L x W x H): 2.2 x 0.9 x 0.9 m; Chamber volume: 1.68 m³; Load volume: 0.88 m³
- External height (inc. stack): 3,300 mm; External height (ex. stack): 2,198 mm
- Weight (est.): 2.9 Tonne (approx. 6,394 lbs)
- Load height from ground: 1,000 mm
- Electric consumption: 0.3 kW
- Optional extras: Grate Bars, USB Data Logger, Ash Door, Stack Extensions, Ash Rake, Heat Exchange system, Larger Control Panel, Service Kits
- Warranty: 3 years standard